| Cervical Length In Preterm Labor Prediction
The Institute for Advanced Medical Education is accredited by the Accreditation Council for Continuing Medical Education (ACCME) to provide continuing medical education for physicians. The Institute for Advanced Medical Education designates this educational activity for a maximum of 1 AMA PRA Category 1 Credit(s) TM. Physicians should only claim credit commensurate with the extent of their participation in the activity. | ||||||||
|
These credits are accepted by the American Registry for Diagnostic Medical Sonography (ARDMS). Faculty: Course: Cervical Length In Preterm Labor Prediction Target Audience: Physicians, sonographers and others who perform and/or interpret obstetrical ultrasound. System requirements: In order to complete this program you must have a computer with a recent version of Internet Explorer or Netscape, and a printer, which is configured to print from the browser. For any questions or problems concerning this program or for problems related to the printing of the certificate please contact IAME at (914) 921-5700 or email us. Estimated Time for Completion of tutorial: One hour Disclosure: In compliance with the Essentials and Standards of the ACCME, the author of this CME tutorial is required to disclose any significant financial or other relationships they may have with the manufacturer(s) of any commercial product(s) or provider(s) of any commercial service(s) discussed in this program. Dr. Lyndon Hill discloses no relevant financial relationships with commercial interests. IAME discloses no relevant financial relationships with commercial interests.
|
||||||||
|
Cervical Length In Preterm Labor Prediction
Objectives
Introduction Methods to assess cervical lengths have gradually evolved over the past decade. The expansion of the bladder that is required with the transabdominal approach results in cervical lengthening (Fig. 1). The translabial or transperineal technique (Fig. 2) is not always successful because of reduced visualization secondary to bowel gas 2 . The transvaginal approach has, therefore, become the accepted method for cervical length assessment. Cervical length is inversely related to the risk of preterm labor 3 . The specific reason or reasons for this association have yet to be defined. Uterine contractions and the inherent tensile strength of the cervix undoubtedly play a role. Bacterial vaginosis is a known risk factor for preterm delivery. Hence, the cervix may also act as a barrier between the vagina and amniotic cavity 4 . Manual Cervical ExaminationThe manual assessment of cervical length is subjective and has poor intraobserver variability 5 . The cervix starts to shorten and dilate at the internal cervical os. This process cannot be appreciated on a digital examination. In women with a diagnosis of preterm labor, the transvaginal examination of the cervix has been found to be superior to a digital exam in predicting preterm delivery 6 . Rozenberg et al 7 have stopped utilizing digital exams in their unit on patients with symptoms of preterm labor. A cervical length < 26 mm with at least 2 contractions in 10 minutes before 34 weeks' gestation are used as criteria for admission and treatment. Transvaginal Cervical Examination A dynamically changing cervix has been associated with uterine contractions. In term women in labor, the cervix shortens approximately 50% during a contraction 9 . Some authors have recommended fundal pressure in an attempt to mimic this effect on the cervix. The presence of induced cervical shortening has been found in some studies to increase the positive predictive value of the cervical measurement in diagnosing preterm labor. Other authors have not found this to be the case 10 . In order to evaluate the cervix for the dynamic changes that occurs in 50% of women with preterm labor, a 10-minute observation period is required 11 . A dynamically changing cervix, either spontaneously, or after fundal pressure, improves the predictive accuracy of cervical length in predicting preterm delivery 12 . Focal myometrial contractions may obscure the internal cervical os and result in a longer measurement (Fig. 6).
In most studies the addition of cervical funneling does not improve the predictive accuracy of cervical length in preterm labor prediction (Fig. 7) 13 . This may, in part, be due to the wide variations noted in funnel measurement. Rust et al 14 have found that as a categorical variable (present or absent), a funnel is a significant risk factor for preterm labor. However, the latter study had a small sample size and was retrospective in nature. Additional prospective studies will be required to determine if the presence of a funnel adds to the predictive accuracy of cervical length in predicting preterm delivery.
Cervical length is a continuous variable, with a mean of 35 mm to 40 mm. A cervical length of 25 mm has generally been found to be at the 10 th percentile 3,15 . When should cervical length be measured?Most patients who deliver preterm will have a cervical length < 25 mm between 16 and 22 weeks' gestation 16 . A cervical length < 25 mm rarely occurs before 14 weeks' gestation. Since the lower uterine segment may not have developed, a short cervix is difficult to identify at < 14 weeks' gestation. The bladder reflection has generally been considered the boundary between the lower uterine segment and cervix. There is a gradually progressive shortening of cervical length after 30 weeks' gestation 17 . For patients at highest risk for preterm delivery (prior 24 week delivery, 2nd trimester losses), an initial examination at 15 to 16 weeks should be considered. For patients at a lower risk (cone biopsy, uterine malformations), a first exam could be obtained during the 18 to 20 weeks anatomy scan. Fetal FibronectinFibronectin is a glycoprotein present in amniotic membranes and decidua. It is released by inflammatory mediated damage to the placenta or membranes 18 . Fetal fibronectin in cervical secretions after 20 weeks' gestation is associated with preterm labor 19 . Cervical length and fetal fibronectin may identify different patients at risk for preterm labor. The predictive accuracy of either test is based on the pretest probability of preterm labor in the population under investigation 20 . Honest et al 18 conducted a meta-analysis of 40 studies in women with symptoms of preterm labor and of 28 studies of women without symptoms of labor. In the asymptomatic and symptomatic groups a positive fibronectin had a likelihood ratio (LR) of 4.01 and 5.42, respectively. The LR of a negative fibronectin was 0.78 and 0.25 for the asymptomatic and symptomatic women, respectively. Fetal fibronectin is most accurate in predicting preterm labor within 7 to 10 days among women with symptoms of preterm labor. Cervical length in high-risk patientsIn low-risk women, there is an increased risk of preterm labor as cervical length decreases. However, only 25% of low-risk women with a short cervix deliver early 3 . In a high-risk population, 75% with a cervical length <= 25 mm at 16-18 weeks' will deliver prematurely 12 . 532 pregnancies from 3 studies presented with preterm labor at 24-36 weeks' gestation. If the cervical length was < 15 mm, delivery occurred within 3 days 21 . As a patient's number of preterm births increases and the gestational age at preterm delivery decreases, the likelihood of another preterm delivery rises by 3 to 4-fold. Yost and co-workers 22 found that these historical variables did not affect the predictive accuracy of a cervical length < 25 mm between 16 and 19 weeks' gestation. However, because of the small sample size, the power of the study to detect a clinically significant difference was low. Until additional studies are reported, prior preterm delivery should be considered a categorical variable that increases the risk of preterm labor. A cervical length <= 25 mm has a 13-fold risk for preterm delivery in women with uterine anomalies. In one study of 64 pregnant women with uterine anomalies, the sensitivity, specificity, positive and negative predictive values of a cervical length <= 25 mm for preterm delivery were 71%, 91%, 50%, and 96%, respectively 23 . The positive predictive value is higher if an abnormally shortened cervix was detected at 14 to 18 weeks in contrast to 18 to 22 weeks 24 . In a blinded study of patients with a history of preterm deliveries, a shortened cervical length had a sensitivity and positive predictive value of 69% and 55%, respectively in predicting preterm labor 12 . Hence, patients at highest risk may be evaluated between 14 and 18 weeks' gestation, while those at slightly lower risk need not be evaluated until 18 to 22 weeks 25 . Faster rates of cervical shortening between 16 and 24 weeks' gestation is an additional independent factor associated with an increased prevalence of preterm labor 26 . The rate of cervical shortening in cases of incompetent cervix diagnosed between 15 and 19 weeks' gestation is - 0.52 cm/week. Between 15 and 24 weeks' gestation the length of a competent cervix is essentially unchanged 26 . Chorioamniotic membrane visualization at the internal cervical os indicates disruption of the decidua-membrane interface and is an independent risk factor for preterm delivery (Fig. 8). Finally, minimal (1-4 mm) endocervical canal dilatation has been associated with an increased risk of preterm labor (Fig. 9) 27 .
Short cervix and intrauterine infection Twins Cervical length <= 25 mm at 18 weeks (likelihood ratio + 9.7, sensitivity 14.3%) and < 22 mm at 24 weeks (likelihood ratio + 9.6, sensitivity 28.6%) were found to be the best predictors of preterm labor in twins. The poor sensitivity of cervical length as a predictor of preterm labor in twins makes it unsuitable as a single test. The negative predictive value of a long cervix has also been evaluated. It has been suggested that cervical length > 35 mm at 24-26 weeks' gestation predicts that a twin pregnancy will deliver at term (negative predictive value 86% - 97%) 31,32 . However, the likelihood ratio of 0.54 to 0.80 indicates that this is not a valuable predictor of delivery >= 35 weeks 31,32 . 3D Cervical Assessment
Severi et al 35 also found a significant difference (p < 0.001) between cervical length measured with 2D ultrasound (37.6 mm) and 3D ultrasound (39.8 mm). A correct, mid-sagittal plane was more accurately determined with 3D in contrast to 2D ultrasound 35 . Whether the difference in cervical length between the 2 measurement techniques is clinically significant remains to be determined. Cerclage for a short cervix on transvaginal ultrasoundBerghella et al 36 performed a meta-analysis of 4 properly conducted trials that included a total of 305 cerclage patients and 302 controls. A cervical cerclage did not prevent preterm birth in all women with a shortened cervical length. In twins the placement of a cerclage was associated with an increased incidence of preterm birth. In a sub-group of patients with a history of a prior preterm birth, cerclage may reduce the preterm birth rate. Cervical length generally increases after a cerclage. The lengthening of the cervix after cerclage is associated with a higher likelihood of a term delivery 37,38 . A cervical length < 25 mm or a cervical length of < 10 mm above the suture have been found to be predictive of preterm labor (Fig. 11) 38 .
Conclusions The incidence of preterm birth remains around 12% 1 . Preterm labor is a heterogeneous process. The presence of multiple interactive continuous variables explains the relatively low predictive value of any one variable. A transvaginal assessment of cervical length is one of the best tests for predicting preterm birth. A cervical length < 25 mm (10 th percentile) between 15 and 24 weeks' gestation is generally agreed upon as increasing the risk of preterm labor. The shorter the cervical length, the greater the likelihood of preterm labor. The positive predictive value of a 25 mm cervix for preterm labor is dependent upon the patient's pretest probability (i.e. high-risk or low-risk for preterm labor). In a low-risk population, cervical length is not an effective screening tool 3 . Because of the low prevalence of disease, the sensitivity of cervical length is decreased and the false positive rate is increased. In order to improve the positive predictive value of a cervical length measurement in low-risk women, a length of 15 mm (0.6% 39 - 1.6% 40 ) rather than 25 mm should be considered too short. Prior spontaneous preterm birth, fetal fibronectin, cervical length, and bacterial vaginosis are associated with early preterm birth. The association of the first 3 with preterm delivery is more than additive 41 . These associations indicate that there is more than one pathway resulting in preterm delivery. In the future, a multifactorial assessment of patients at risk for preterm delivery should improve the positive predictive value of our testing schema. Specific therapeutic regimens depending upon the etiology or etiologies of preterm labor will be required and should improve our current limited successfully inhibition of preterm labor. References
If you are using a voucher please enter your email address exactly as you did when you made your original purchase. IAME
Statement on Privacy and Confidentiality
|
||||||||